Glucocard G blood glucose apparatus

The device does not need calibration. Micro drop of 0.6 µL. It is possible to obtain this amount of blood sample using the Glucoject Dual S and Glucoject Lancets No-dol accessories. Sample volume control. Blood glucose measurement starts only when the required amount of sample is applied to the test strip. Sample collection at an alternate site. Results in 15 seconds. Automatically stores 360 memory results with date and time. Allows you to average the last 14 or 30 days. Results can be transferred to the computer using the MenaDiab program.

  • Availability: In stock
  • Brand: A.Menarini
  • SKU: 33935
39.22 €

GLUCOCARD G sensor
  • Meter - Only with GLUCOCARD G + and GLUCOCARD G meter;
  • Measurement technology - Electrochemical;
  • Sample volume - 0.6 µL;
  • Response time - 5.5 seconds;
  • Reading limits - 10-600 mg/dL;
  • Enzyme system - FAD-GDH (Flavin Adenine Dinucleotide - Glucose Dehygrogenase)
  • Interference - No interference with Maltose or Galactose. Interference with paracetamol, ascorbic acid and uric acid is reduced;
  • Shelf life - 1 year and 6 months from manufacture. The end of shelf life is 6 months after the date of opening of the bottle.
Glucoject Dual Accessory

The comfort zone technology makes the capillary puncture much less painful. Damage or injury to the skin causes the receptors to transmit pain signals to the brain through the spinal cord. Through the particular Comfort Zone Technology (CZT), Glucoject Dual S uses eight raised points to apply pressure on the nerve fibers in the finger and send a message of comfort to the brain, dissimulating the message of pain. According to the "gate theory", the tactile stimulus of the brain is transmitted by the large nerve fibers that obstruct the passage of pain stimulus, transmitted, in turn, by the smaller nerve fibers. In this way, the Glucoject Dual S , thanks to 8 salient points, allows reducing the sensation of pain when the lancet penetrates the skin to collect the capillary blood sample. Thanks to the CZT, Glucoject Dual S increases the comfort masking the perception making the capillary puncture much less painful.

  • There are 21 possibilities to personalize your lancing device.
  • It has 3 force adjustments.
  • With 7 penetration depth settings (0 minimum depth, 6 maximum depth).
  • AST Adapter - Used for Alternative Test Site
Accessory Lancets Glucoject No-Dol:
  • Processing Phases: Sharpen - Polish, Seal - Sterilize.
  • Glucoject No-Dol Lancets are compatible with the majority of lancing devices on the market
  • Glucoject Dual S can only be used with Glucoject Lancets No-Dol.

Details

Teste
Whole Blood Glucose
Sample Volume
0,6 µL
Test strips
GLUCOCARD G sensor (only)
Reading limits
10-600 mg/dL
Reading time
15 seconds
Operating environment
Temperature 10-40 °C; Relative humidity 20-80% (non-condensing)
Data transmission
A plug for connection to the computer
Power Supply
3 V Lithium Battery (CR2032 or DL2032)
Battery life
Approximately 2000 tests (depending on type of use)
Low battery indication
Display of the battery symbol
Memory
360 test results
Dimensions
52 x 90 x 16 mm
Weight
Approximately 53 g (with battery)
Diameter (Glucoject No-Dol Lancets)
30G (0,315 mm)
Lenght (Glucoject No-Dol Lancets)
3,3 mm
Geometric Needle (Glucoject No-Dol Lancets)
3 sides of blade
Sterilization (Glucoject No-Dol Lancets)
Gamma radiation
Use (Glucoject No-Dol Lancets)
Disposable
Material (Glucoject No-Dol Lancets)
Steel, no latex